← Back to Cable List

Product Name

IB-YSLCY 10×1,0

Performance Characteristics

PN-EN50575
PN-EN50575
Indoor application
Indoor application
Outdoor application
Outdoor application
Flame retardant PN-EN 60332-1-2
Flame retardant PN-EN 60332-1-2
UV resistance
UV resistance
Oil resistance
Oil resistance

Application

TECHNOKONTROL IB-YSLCY are overall shielded cables, intended for intrinsically safe circuits and explosive conditions zones, designed for the operating voltage 300/500 V. The overall shield protects the cables against external electromagnetic interferences and prevents emission of interferences produced in the cables. The cables are designed to offer high flexibility combined with tensile strength. Sheathing PVC of high oxygen index is UV radiation and weather resistant, is self-extinguishing and flame retardant. The cables pass combustibility test according to PN-EN 60332-3 standard. The cables are oil-resistant and designed for frequent contact with petroleum products, as in petrol stations and stores, where engine fuels and lubricants are pumped or handled. The cables are suitable for fixed indoor and outdoor installations.

Structure

 
  • flexible, multiwire conductors, stranded of bare annealed copper wires (tin-plated on request), meeting require­ments of class 2 per PN-EN 60228,
  • black PVC insulation and white conductor numbers printed on it for identification,
  • insulated conductors laid-up in layers,
  • cable core wrapped in polyester tape,
  • tinned copper wire braid shield of effective density coverage,
  • oil, petrol and UV radiation resistant and self-extinguishing (oxygen index bigger than 29%) PVC cable sheath, blue RAL 5015 according to VDE 0165 6.1.3.2.3.
Conductor cross-section mm2 0,5 0,75 1,0 1,5 2,5
Maximum DC conductor resistance at 20°C Ω/km 36 24,5 18,1 12,1 7,41
Capacitance between conductors at 1 kHz, appr. nF/km 160 170 180 180 200
Characteristics Descritpion
Operating voltage Uo/U 300/500 V
Voltage test 3,0 kV sk
Minimum insulation resistance 20 MΩ·km
Inductance, approximate 0,7 mH/km
Operating temperature range for fixed installation from - 30 to + 80°C
Operating temperature range for movable installation from - 5 to + 70°C
Minimum bending radius 10 x cable diameter
Cable combustibillity flame retardant
Combustibillity tests PN-EN 60332-1-2, IEC 60332-1-2
Oil resistance PN-EN 60811-404
Reference standards DT 28/01/04
CPR-class reaction on fire Eca
DoP declarations are available at www.technokabel.com.pl
The cable meets requirements of the low voltage direction 2014/35/UE

Available Upon Request

TECHNOKONTROL IB-YSLCEY - cables with drain wire stranded of tin-plated annealed copper wires (class 2), laid under a shield. TECHNOKONTROL IB-YSLCYv - intrinsically safe cables with enhanced PVC sheath, suitable for outdoor installations and direct earth burial.
Item Index Item Name CPR Class Outer Diameter (approx.) mm Cable Weight (approx.) kg/km Cu Index
Item Index: 0581 054 20 Item Name: IB-YSLCY 24×0,75 CPR Class: Eca Outer Diameter (approx.) mm: 13.6 Cable Weight (approx.) kg/km: 311 Cu Index: 202.4
Item Index: 0581 055 20 Item Name: IB-YSLCY 27×1,5 CPR Class: Eca Outer Diameter (approx.) mm: 17 Cable Weight (approx.) kg/km: 586 Cu Index: 434
Item Index: 0581 056 20 Item Name: IB-YSLCY 5×2,5 CPR Class: Eca Outer Diameter (approx.) mm: 10.2 Cable Weight (approx.) kg/km: 207 Cu Index: 141.4
Item Index: 0581 059 20 Item Name: IB-YSLCY 8×0,5 CPR Class: Eca Outer Diameter (approx.) mm: 7.3 Cable Weight (approx.) kg/km: 91 Cu Index: 50
Item Index: 0581 081 20 Item Name: IB-YSLCY 30×0,75 CPR Class: Eca Outer Diameter (approx.) mm: 14.6 Cable Weight (approx.) kg/km: 378 Cu Index: 247.6
Item Index: 0581 093 20 Item Name: IB-YSLCY 36×1,0 CPR Class: Eca Outer Diameter (approx.) mm: 17 Cable Weight (approx.) kg/km: 566 Cu Index: 390.8
Item Index: 0581 041 20 Item Name: IB-YSLCY 16×2,5 CPR Class: Eca Outer Diameter (approx.) mm: 16.6 Cable Weight (approx.) kg/km: 567 Cu Index: 427.9
Item Index: 0581 042 20 Item Name: IB-YSLCY 4×0,5 CPR Class: Eca Outer Diameter (approx.) mm: 5.8 Cable Weight (approx.) kg/km: 54 Cu Index: 28.9
Item Index: 0581 043 20 Item Name: IB-YSLCY 10×0,5 CPR Class: Eca Outer Diameter (approx.) mm: 8.6 Cable Weight (approx.) kg/km: 113 Cu Index: 67
Item Index: 0581 044 20 Item Name: IB-YSLCY 30×0,5 CPR Class: Eca Outer Diameter (approx.) mm: 13.2 Cable Weight (approx.) kg/km: 290 Cu Index: 172.5
Item Index: 0581 047 20 Item Name: IB-YSLCY 16×0,5 CPR Class: Eca Outer Diameter (approx.) mm: 10.1 Cable Weight (approx.) kg/km: 171 Cu Index: 98.5
Item Index: 0581 048 20 Item Name: IB-YSLCY 24×1,0 CPR Class: Eca Outer Diameter (approx.) mm: 14.9 Cable Weight (approx.) kg/km: 393 Cu Index: 262.8
Item Index: 0581 049 20 Item Name: IB-YSLCY 14×1,5 CPR Class: Eca Outer Diameter (approx.) mm: 12.7 Cable Weight (approx.) kg/km: 320 Cu Index: 228.8
Item Index: 0581 032 20 Item Name: IB-YSLCY 4×1,5 CPR Class: Eca Outer Diameter (approx.) mm: 7.4 Cable Weight (approx.) kg/km: 102 Cu Index: 69.4
Item Index: 0581 050 20 Item Name: IB-YSLCY 12×0,5 CPR Class: Eca Outer Diameter (approx.) mm: 8.8 Cable Weight (approx.) kg/km: 128 Cu Index: 76.6
Item Index: 0581 033 20 Item Name: IB-YSLCY 6×0,75 CPR Class: Eca Outer Diameter (approx.) mm: 7.4 Cable Weight (approx.) kg/km: 95 Cu Index: 55
Item Index: 0581 051 20 Item Name: IB-YSLCY 12×1,0 CPR Class: Eca Outer Diameter (approx.) mm: 10.8 Cable Weight (approx.) kg/km: 209 Cu Index: 138.1
Item Index: 0581 034 20 Item Name: IB-YSLCY 12×1,5 CPR Class: Eca Outer Diameter (approx.) mm: 12.1 Cable Weight (approx.) kg/km: 282 Cu Index: 198.5
Item Index: 0581 052 20 Item Name: IB-YSLCY 10×1,0 CPR Class: Eca Outer Diameter (approx.) mm: 10.4 Cable Weight (approx.) kg/km: 183 Cu Index: 117.8
Item Index: 0581 035 20 Item Name: IB-YSLCY 16×1,0 CPR Class: Eca Outer Diameter (approx.) mm: 12.1 Cable Weight (approx.) kg/km: 273 Cu Index: 179.3
Item Index: 0581 053 20 Item Name: IB-YSLCY 6×1,0 CPR Class: Eca Outer Diameter (approx.) mm: 8 Cable Weight (approx.) kg/km: 119 Cu Index: 74.2
Item Index: 0581 036 20 Item Name: IB-YSLCY 32×1,0 CPR Class: Eca Outer Diameter (approx.) mm: 16.4 Cable Weight (approx.) kg/km: 516 Cu Index: 350.6
Item Index: 0581 037 20 Item Name: IB-YSLCY 48×1,0 CPR Class: Eca Outer Diameter (approx.) mm: 19.6 Cable Weight (approx.) kg/km: 734 Cu Index: 513.5
Item Index: 0581 038 20 Item Name: IB-YSLCY 16×1,5 CPR Class: Eca Outer Diameter (approx.) mm: 13.4 Cable Weight (approx.) kg/km: 363 Cu Index: 259.4
Item Index: 0581 039 20 Item Name: IB-YSLCY 48×1,5 CPR Class: Eca Outer Diameter (approx.) mm: 21.8 Cable Weight (approx.) kg/km: 991 Cu Index: 750.7
Item Index: 0581 040 20 Item Name: IB-YSLCY 7×0,5 CPR Class: Eca Outer Diameter (approx.) mm: 6.8 Cable Weight (approx.) kg/km: 78 Cu Index: 44.2
Item Index: 0581 022 20 Item Name: IB-YSLCY 3×0,5 CPR Class: Eca Outer Diameter (approx.) mm: 5.4 Cable Weight (approx.) kg/km: 44 Cu Index: 22.5
Item Index: 0581 023 20 Item Name: IB-YSLCY 20×0,75 CPR Class: Eca Outer Diameter (approx.) mm: 12.3 Cable Weight (approx.) kg/km: 272 Cu Index: 170.2
Item Index: 0581 024 20 Item Name: IB-YSLCY 7×1,0 CPR Class: Eca Outer Diameter (approx.) mm: 8 Cable Weight (approx.) kg/km: 125 Cu Index: 83.8
Item Index: 0581 025 20 Item Name: IB-YSLCY 8×1,0 CPR Class: Eca Outer Diameter (approx.) mm: 8.6 Cable Weight (approx.) kg/km: 145 Cu Index: 95.8
Item Index: 0581 026 20 Item Name: IB-YSLCY 18×0,75 CPR Class: Eca Outer Diameter (approx.) mm: 11.6 Cable Weight (approx.) kg/km: 241 Cu Index: 154.5
Item Index: 0581 027 20 Item Name: IB-YSLCY 25×0,75 CPR Class: Eca Outer Diameter (approx.) mm: 13.9 Cable Weight (approx.) kg/km: 331 Cu Index: 210.3
Item Index: 0581 028 20 Item Name: IB-YSLCY 12×0,75 CPR Class: Eca Outer Diameter (approx.) mm: 10 Cable Weight (approx.) kg/km: 170 Cu Index: 107.1
Item Index: 0581 029 20 Item Name: IB-YSLCY 42×1,0 CPR Class: Eca Outer Diameter (approx.) mm: 18.5 Cable Weight (approx.) kg/km: 665 Cu Index: 452.4
Item Index: 0581 030 20 Item Name: IB-YSLCY 8×0,75 CPR Class: Eca Outer Diameter (approx.) mm: 8 Cable Weight (approx.) kg/km: 118 Cu Index: 74.2
Item Index: 0581 031 20 Item Name: IB-YSLCY 35×1,0 CPR Class: Eca Outer Diameter (approx.) mm: 17 Cable Weight (approx.) kg/km: 559 Cu Index: 381.2
Item Index: 0581 015 20 Item Name: IB-YSLCY 19×1,5 CPR Class: Eca Outer Diameter (approx.) mm: 14.3 Cable Weight (approx.) kg/km: 422 Cu Index: 304.5
Item Index: 0581 016 20 Item Name: IB-YSLCY 2×0,75 CPR Class: Eca Outer Diameter (approx.) mm: 5.5 Cable Weight (approx.) kg/km: 43 Cu Index: 22.5
Item Index: 0581 017 20 Item Name: IB-YSLCY 7×0,75 CPR Class: Eca Outer Diameter (approx.) mm: 7.4 Cable Weight (approx.) kg/km: 99 Cu Index: 62.2
Item Index: 0581 018 20 Item Name: IB-YSLCY 7×1,5 CPR Class: Eca Outer Diameter (approx.) mm: 8.8 Cable Weight (approx.) kg/km: 165 Cu Index: 119.8
Item Index: 0581 021 20 Item Name: IB-YSLCY 3×1,0 CPR Class: Eca Outer Diameter (approx.) mm: 6.2 Cable Weight (approx.) kg/km: 64 Cu Index: 38.5
Item Index: 0581 007 20 Item Name: IB-YSLCY 5×0,75 CPR Class: Eca Outer Diameter (approx.) mm: 6.8 Cable Weight (approx.) kg/km: 79 Cu Index: 46.6
Item Index: 0581 008 20 Item Name: IB-YSLCY 3×0,75 CPR Class: Eca Outer Diameter (approx.) mm: 5.8 Cable Weight (approx.) kg/km: 54 Cu Index: 31.3
Item Index: 0581 009 20 Item Name: IB-YSLCY 5×1,5 CPR Class: Eca Outer Diameter (approx.) mm: 8.1 Cable Weight (approx.) kg/km: 130 Cu Index: 88.9
Item Index: 0581 010 20 Item Name: IB-YSLCY 2×1,0 CPR Class: Eca Outer Diameter (approx.) mm: 5.9 Cable Weight (approx.) kg/km: 51 Cu Index: 28.9
Item Index: 0581 011 20 Item Name: IB-YSLCY 2×2,5 CPR Class: Eca Outer Diameter (approx.) mm: 7.7 Cable Weight (approx.) kg/km: 91 Cu Index: 60.4
Item Index: 0581 012 20 Item Name: IB-YSLCY 6×0,5 CPR Class: Eca Outer Diameter (approx.) mm: 6.8 Cable Weight (approx.) kg/km: 75 Cu Index: 39.4
Item Index: 0581 013 20 Item Name: IB-YSLCY 3×2,5 CPR Class: Eca Outer Diameter (approx.) mm: 8.2 Cable Weight (approx.) kg/km: 124 Cu Index: 89.1
Item Index: 0581 014 20 Item Name: IB-YSLCY 4×2,5 CPR Class: Eca Outer Diameter (approx.) mm: 9 Cable Weight (approx.) kg/km: 156 Cu Index: 115.2
Item Index: 0581 001 20 Item Name: IB-YSLCY 2×0,5 CPR Class: Eca Outer Diameter (approx.) mm: 5.1 Cable Weight (approx.) kg/km: 36 Cu Index: 17.6
Item Index: 0581 002 20 Item Name: IB-YSLCY 4×0,75 CPR Class: Eca Outer Diameter (approx.) mm: 6.3 Cable Weight (approx.) kg/km: 65 Cu Index: 38.5
Item Index: 0581 003 20 Item Name: IB-YSLCY 4×1,0 CPR Class: Eca Outer Diameter (approx.) mm: 6.7 Cable Weight (approx.) kg/km: 78 Cu Index: 48.8
Item Index: 0581 004 20 Item Name: IB-YSLCY 5×1,0 CPR Class: Eca Outer Diameter (approx.) mm: 7.3 Cable Weight (approx.) kg/km: 97 Cu Index: 59.6
Item Index: 0581 005 20 Item Name: IB-YSLCY 2×1,5 CPR Class: Eca Outer Diameter (approx.) mm: 6.4 Cable Weight (approx.) kg/km: 63 Cu Index: 38.6
Item Index: 0581 006 20 Item Name: IB-YSLCY 3×1,5 CPR Class: Eca Outer Diameter (approx.) mm: 6.8 Cable Weight (approx.) kg/km: 82 Cu Index: 53.8