← Back to Cable List

Product Name

(N)HXCH FE180 PH90/E90 0,6/1 kV 7×1,5/2,5 RE

Performance Characteristics

PN-EN50575
PN-EN50575
Indoor application
Indoor application
Outdoor application
Outdoor application
Functional integrity
Functional integrity
Circuit integrity E90 DIN VDE 4102-12
Circuit integrity E90 DIN VDE 4102-12
Flame retardant PN-EN 60332-1-2
Flame retardant PN-EN 60332-1-2
Halogen-free
Halogen-free
UV resistance
UV resistance

Application

TECHNOFLAME (N)HXCH FE180 PH90/E90 0,6/1 kV fire resistant and halogen free power cables, are intended for power supply to fire protection equipment in objects of sharp fire protection requirements, particularly in fire alarm and fire automatic control systems. The cables shall be applied in locations where, in case of fire, higher safety for human beings and expensive electronic equipment is required (subway tunnels, hospitals, shopping centres, supermarkets, cinemas, theatres, stadiums and other public buildings). Functions of the cables are maintained for 90 minutes – power is supplied to equipment which must operate in fire conditions and during fire fighting (e.g. water pumps in fire extinguishing systems, smoke removing fans, emergency lighting and elevators). The cables are certified by Scientific and Research Centre for Fire Protection - National Research Institute (Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej - PIB) at Józefów. The cables can not be used in fire protected rooms with fixed pressure water spraying fire extinguishing systems (sprinkler zones). The cables are flame retardant and their smoke emission is low, emitted fumes are non toxic and non corrosive. The cables are suitable for fixed indoor and outdoor installations. Sheathing is UV radiation resistant. Laying cables in water or direct earth burial are only permitted if additional protection is used.

Structure

 
  • bare annealed copper conductors meeting requirements of PN-EN 60228 standard:
RE - class 1 single wire round conductor, RM - class 2 multiwire round conductor,
  • double special cross-linked silicone rubber insulation – colours:
up to 5 wires in accordance with PN-HD 308, above 5 wires black and white conductor number printed on it,
  • insulated conductors laid-up into a cable core,
  • inner covering made of halogen free compound,
  • concentric conductor formed by bare copper wires with counter helix of copper tape over the inner sheath,
  • concentric conductor wrapped in polyester tape,
  • orange cable sheath made of halogen free compound type HM4 according to HD 604 S1.
Conductor cross-section mm2 1,5 2,5 4 6 10 16 25 35 50
Maximum DC conductor resistance at 20°C Ω/km 12,1 7,41 4,61 3,08 1,83 1,15 0,727 0,524 0,387

Cable installation – should be carried out on a certified cable fastening system, in accordance with the National Technical Assessments (KOT) issued for fastening manufacturers. Only certified cable fixing systems, tested according to DIN 4102 part 12, should be used.

Characteristics Descritpion
Operating voltage Uo/U 0,6/1 kV
Voltage test 4 kV sk
Minimum insulation resistance, at90°C 1011 Ω∙cm
Inductance, approximate 0,7 mH/km
Conductor temperature limit in work conditions + 90°C
Conductor temperature limit at short-circuit + 250°C
Operating temperature range during operation from - 30 to + 90°C
Operating temperature range during installation from - 5 to + 70°C
Minimum bending radius 15 x cable diameter
Corrosivity of emitted gases per very low, halogen free PN-EN 60754-1, PN-EN 60754-2, IEC 60754-2
pH > 4,3
Conductivity < 2,5 μS/mm
Smoke density PN-EN 61034-2, IEC 61034-2
Light transmittance 60-80 %
Cable combustibillity flame retardant
Combustibillity tests PN-EN 60332-1-2, IEC 60332-1-2, PN-EN 60332-3-24, IEC 60332-3-24,
Circuit integrity: E90 DIN 4102-12
Circuit integrity: PH90 PN-EN 50200 or PN-EN IEC 60331-1
Insulation integrity FE180 IEC 60331-21, IEC 60331-11
Reference standards CNBOP-PIB-KOT-2021/0311-3701 wyd.3, WT-TK-44
Class reaction to fire ( PN-EN 13501-6) B2ca-s1b,d0,a1
DoP declarations are available at technokabel.com.pl
The cable meets requirements of the low voltage direction 2014/35/UE
Item Index Item Name CPR Class Outer Diameter (approx.) mm Cable Weight (approx.) kg/km Cu Index
Item Index: 1222 052 33 Item Name: (N)HXCH FE180 PH90/E90 0,6/1 kV 19×1,5/4 RE CPR Class: Outer Diameter (approx.) mm: 22.7 Cable Weight (approx.) kg/km: 791 Cu Index: 324.3
Item Index: 1222 053 33 Item Name: (N)HXCH FE180 PH90/E90 0,6/1 kV 5×1,5/1,5 RE CPR Class: B2ca-s1b,d0,a1 Outer Diameter (approx.) mm: 14.4 Cable Weight (approx.) kg/km: 300 Cu Index: 92.7
Item Index: 1222 054 33 Item Name: (N)HXCH FE180 PH90/E90 0,6/1 kV 2×16/16 RE CPR Class: B2ca-s1b,d0,a1 Outer Diameter (approx.) mm: 19.5 Cable Weight (approx.) kg/km: 792 Cu Index: 473.1
Item Index: 1222 055 33 Item Name: (N)HXCH FE180 PH90/E90 0,6/1 kV 2×2,5/2,5 RE CPR Class: B2ca-s1b,d0,a1 Outer Diameter (approx.) mm: 13 Cable Weight (approx.) kg/km: 255 Cu Index: 78.3
Item Index: 1222 043 33 Item Name: (N)HXCH FE180 PH90/E90 0,6/1 kV 3×25/16 RM CPR Class: B2ca-s1b,d0,a1 Outer Diameter (approx.) mm: 24.9 Cable Weight (approx.) kg/km: 1347 Cu Index: 0
Item Index: 1222 045 33 Item Name: (N)HXCH FE180 PH90/E90 0,6/1 kV 7×2,5/2,5 RE CPR Class: B2ca-s1b,d0,a1 Outer Diameter (approx.) mm: 16.9 Cable Weight (approx.) kg/km: 470 Cu Index: 198.3
Item Index: 1222 046 33 Item Name: (N)HXCH FE180 PH90/E90 0,6/1 kV 3×35/16 RM CPR Class: B2ca-s1b,d0,a1 Outer Diameter (approx.) mm: 27.4 Cable Weight (approx.) kg/km: 1703 Cu Index: 0
Item Index: 1222 047 33 Item Name: (N)HXCH FE180 PH90/E90 0,6/1 kV 3×50/25 RM CPR Class: B2ca-s1b,d0,a1 Outer Diameter (approx.) mm: 30.9 Cable Weight (approx.) kg/km: 2305 Cu Index: 0
Item Index: 1222 048 33 Item Name: (N)HXCH FE180 PH90/E90 0,6/1 kV 7×1,5/2,5 RE CPR Class: B2ca-s1b,d0,a1 Outer Diameter (approx.) mm: 15.8 Cable Weight (approx.) kg/km: 380 Cu Index: 0
Item Index: 1222 049 33 Item Name: (N)HXCH FE180 PH90/E90 0,6/1 kV 12×1,5/2,5 RE CPR Class: B2ca-s1b,d0,a1 Outer Diameter (approx.) mm: 19.4 Cable Weight (approx.) kg/km: 558 Cu Index: 209.2
Item Index: 1222 050 33 Item Name: (N)HXCH FE180 PH90/E90 0,6/1 kV 2×50/25 RM CPR Class: B2ca-s1b,d0,a1 Outer Diameter (approx.) mm: 29 Cable Weight (approx.) kg/km: 1866 Cu Index: 1212.3
Item Index: 1222 051 33 Item Name: (N)HXCH FE180 PH90/E90 0,6/1 kV 2×1,5/1,5 RE CPR Class: B2ca-s1b,d0,a1 Outer Diameter (approx.) mm: 12 Cable Weight (approx.) kg/km: 198 Cu Index: 49.3
Item Index: 1222 017 33 Item Name: (N)HXCH FE180 PH90/E90 0,6/1 kV 14×2,5/4 RE CPR Class: Outer Diameter (approx.) mm: 22.4 Cable Weight (approx.) kg/km: 815 Cu Index: 386.8
Item Index: 1222 040 33 Item Name: (N)HXCH FE180 PH90/E90 0,6/1 kV 3×6/6 RE CPR Class: B2ca-s1b,d0,a1 Outer Diameter (approx.) mm: 16.4 Cable Weight (approx.) kg/km: 472 Cu Index: 236.7
Item Index: 1222 011 33 Item Name: (N)HXCH FE180 PH90/E90 0,6/1 kV 4×10/10 RE CPR Class: B2ca-s1b,d0,a1 Outer Diameter (approx.) mm: 20 Cable Weight (approx.) kg/km: 799 Cu Index: 492.3
Item Index: 1222 012 33 Item Name: (N)HXCH FE180 PH90/E90 0,6/1 kV 4×16/16 RM CPR Class: B2ca-s1b,d0,a1 Outer Diameter (approx.) mm: 23.2 Cable Weight (approx.) kg/km: 1174 Cu Index: 780.3
Item Index: 1222 013 33 Item Name: (N)HXCH FE180 PH90/E90 0,6/1 kV 4×25/16 RM CPR Class: B2ca-s1b,d0,a1 Outer Diameter (approx.) mm: 27.3 Cable Weight (approx.) kg/km: 1654 Cu Index: 1125.9
Item Index: 1222 014 33 Item Name: (N)HXCH FE180 PH90/E90 0,6/1 kV 4×35/16 RM CPR Class: B2ca-s1b,d0,a1 Outer Diameter (approx.) mm: 29.8 Cable Weight (approx.) kg/km: 2088 Cu Index: 1509.9
Item Index: 1222 015 33 Item Name: (N)HXCH FE180 PH90/E90 0,6/1 kV 12×2,5/4 RE CPR Class: B2ca-s1b,d0,a1 Outer Diameter (approx.) mm: 21.7 Cable Weight (approx.) kg/km: 845 Cu Index: 326
Item Index: 1222 016 33 Item Name: (N)HXCH FE180 PH90/E90 0,6/1 kV 4×95/50 RM CPR Class: Outer Diameter (approx.) mm: 44.9 Cable Weight (approx.) kg/km: 5516 Cu Index: 4140.3
Item Index: 1222 003 33 Item Name: (N)HXCH FE180 PH90/E90 0,6/1 kV 4×1,5/1,5 RE CPR Class: B2ca-s1b,d0,a1 Outer Diameter (approx.) mm: 13.4 Cable Weight (approx.) kg/km: 265 Cu Index: 78.3
Item Index: 1222 004 33 Item Name: (N)HXCH FE180 PH90/E90 0,6/1 kV 4×50/25 RM CPR Class: B2ca-s1b,d0,a1 Outer Diameter (approx.) mm: 34.2 Cable Weight (approx.) kg/km: 2872 Cu Index: 2172.3
Item Index: 1222 005 33 Item Name: (N)HXCH FE180 PH90/E90 0,6/1 kV 3×1,5/1,5 RE CPR Class: B2ca-s1b,d0,a1 Outer Diameter (approx.) mm: 12.5 Cable Weight (approx.) kg/km: 228 Cu Index: 63.7
Item Index: 1222 006 33 Item Name: (N)HXCH FE180 PH90/E90 0,6/1 kV 3×2,5/2,5 RE CPR Class: B2ca-s1b,d0,a1 Outer Diameter (approx.) mm: 13.5 Cable Weight (approx.) kg/km: 285 Cu Index: 102.3
Item Index: 1222 007 33 Item Name: (N)HXCH FE180 PH90/E90 0,6/1 kV 3×4/4 RE CPR Class: B2ca-s1b,d0,a1 Outer Diameter (approx.) mm: 14.7 Cable Weight (approx.) kg/km: 363 Cu Index: 159.9
Item Index: 1222 008 33 Item Name: (N)HXCH FE180 PH90/E90 0,6/1 kV 4×2,5/2,5 RE CPR Class: B2ca-s1b,d0,a1 Outer Diameter (approx.) mm: 14.5 Cable Weight (approx.) kg/km: 334 Cu Index: 126.3
Item Index: 1222 009 33 Item Name: (N)HXCH FE180 PH90/E90 0,6/1 kV 4×4/4 RE CPR Class: B2ca-s1b,d0,a1 Outer Diameter (approx.) mm: 16 Cable Weight (approx.) kg/km: 436 Cu Index: 198.1
Item Index: 1222 010 33 Item Name: (N)HXCH FE180 PH90/E90 0,6/1 kV 4×6/6 RE CPR Class: B2ca-s1b,d0,a1 Outer Diameter (approx.) mm: 17.6 Cable Weight (approx.) kg/km: 559 Cu Index: 294.3