← Back to Cable List

Product Name

TLYp (L1) 2×0,35

Performance Characteristics

PN-EN50575
PN-EN50575
Indoor application
Indoor application
Flame retardant PN-EN 60332-1-2
Flame retardant PN-EN 60332-1-2

Application

Loudspeaker cables TLYp (L1) and TLgYp (L1) (high flexible) are intended for connection between amplifiers and loudspeakers. The cables are flat with common PVC insulation (eight shape) on two parallel conductors. The cables are designed to offer high acoustic parameters confirmed by testing in Electroacoustic Division, Institute of Radioelectronics Warsaw University of Technology. The cables are suitable for indoor installations connecting fixed and movable equipment.

Structure

  • flexible, multiwire conductors, stranded of bare annealed copper wires,
  • PVC insulation,
  • colours:
  • black with white stripe or white with black stripe (cross-sections 0.35 and 0.5 mm2),
  • transparent with black or red stripe (other cross-sections),
  • other colours also available.
wires TLYp (L1)
Conductor cross-section mm2 0,35 0,5 0,75 1,0 1,5
DC conductor resistance at 20°C maximum Ω/km 55,4 39 26 19,5 13,3
average 54,6 37,4 24,8 18,8 12,3
Inductance, approximate mH/km 422 203 96 51 30
wires TLgYp (L1)
Conductor cross-section mm2 1,5 2,5 4 6 10
DC conductor resistance at 20°C maximum Ω/km 13,3 7,98 4,95 3,3 1,91
average 12,5 7,5 4,7 3 1,8
Inductance, approximate mH/km 30 9 4 2 1,5
Characteristics Descritpion
Minimum insulation resistance 200 MΩ×km
Operating voltage 300 V
Voltage test 1500 V sk
Operating temperature range for fixed installation from - 30 to + 80°C
Operating temperature range for movable installation from - 5 to + 50°C
Minimum bending radius 5 x cable height
Cable combustibillity flame retardant
Combustibillity tests PN-EN 60332-1-2, IEC 60332-1-2
Reference standards WT-00/TK-1
CPR-class reaction on fire Eca
DoP declarations are available at technokabel.com.pl
The cable meets requirements of the low voltage direction 2014/35/UE